The NI PCI-6024E is a multifunction DAQ board for PCI bus systems delivering analog input and output, digital I/O, and counter/timer functionality for test, measurement, and automation applications. The 12-bit device acquires up to 16 single-ended or 8 differential analog channels at 200 kS/s and outputs 2 analog channels at 10 kS/s. Two 24-bit counters support PWM generation with a 20 MHz timebase. An 8-line TTL/CMOS digital I/O port, RTSI synchronization, and dual triggering modes enable multi-function coordination. Compatible with LabVIEW, C/C++, Python, and legacy NI-DAQ drivers across Windows, Linux, and Mac OS X platforms.
Technical Specifications
Analog Input
• 16 single-ended or 8 differential channels
• 12-bit resolution
• 200 kS/s maximum sampling rate
• Input ranges: ±10 V, ±5 V, ±0.5 V, ±0.05 V
• Input impedance: 100 GΩ in parallel with 100 pF
• Referenced single-ended, non-referenced single-ended, and differential input configurations
• Onboard self-calibration and temperature drift protection
Analog Output
• 2 channels
• 12-bit resolution
• 10 kS/s maximum output rate
• ±10 V output range
• 0.1 Ω output impedance
• 5 mA source (10 V) and 5 mA sink (−10 V) current drive
Digital I/O
• 8 independently programmable lines
• TTL/CMOS logic levels
• VCC + 0.5 V input protection
Counter/Timers
• 2 counters, 24-bit resolution
• PWM output support with 20 MHz timebase
Triggering & Synchronization
• Digital triggering via PFI lines
• Analog input triggering on PFI 0
• RTSI bus for multi-function synchronization
• PXI Trigger Bus compatible
Interface & Power
• 68-pin male SCSI-II I/O connector
• +4.65 to +5.25 VDC at 1 A from I/O connector
– Key Features
• Compatible with SCC and SCXI signal conditioning modules
• Supports NI-DAQmx and traditional NI-DAQ drivers
• Software development in LabVIEW, C/C++, Python, Measurement Studio, and LabWindows/CVI
• Compact form factor: 6.9 × 4.2 inches, 4.1 oz
– Typical Applications
Industrial test automation, process monitoring, sensor data logging, and laboratory instrumentation requiring synchronized multi-channel measurements.
– Compatibility & Integration
RTSI bus synchronization with up to five additional NI devices. Signal conditioning via SCC and SCXI modules. Cross-platform support for Windows 2000/NT/XP, Linux, and Mac OS X.