The NI PXI-1052 is a 12-slot hybrid chassis integrating a 4-slot PXI subsystem with an 8-slot SCXI subsystem. This architecture enables seamless measurement and automation applications combining PXI instrumentation with SCXI signal conditioning. The built-in digital and analog bus between subsystems allows a DAQ/DMM module in the fourth PXI slot to control SCXI modules without additional cabling in multiplexed mode, creating a low-noise environment for advanced signal processing.
Technical Specifications
Slot Configuration
• 4 PXI slots (PXI Hardware Specification, Revision 2.1 compliant)
• 8 SCXI slots with built-in power and control circuitry
Power Management
• Maximum usable power: 450 W
• Input frequency: 50/60 Hz with automatic voltage and frequency ranging
• Over-current protection included
• Remote PXI voltage monitoring capability
Thermal Management
• Cooling capacity: 25 W per slot (HIGH fan speed)
• AUTO/HIGH fan-speed selector optimizes cooling and acoustic emissions based on air intake temperature
• Acoustic emissions: 41.6 dBA (AUTO mode), 51.5 dBA (HIGH mode)
Environmental Ratings
• Operating temperature: 0 to 50 °C (IEC 60068-2-1, IEC 60068-2-2 compliant)
• Relative humidity: 10 to 90%, noncondensing (IEC 60068-2-56 compliant)
Physical Specifications
• Dimensions: 16.2 × 17.3 × 7.0 inches (180 × 440 × 450 mm)
• Weight: 29 lbs
• Benchtop mounting with tilt-up or leveling feet; removable feet
• Mounting points for optional rack-mount kits (front and rear)
• Vertical mounting supported with adequate fan space
• Built-in carrying handle
– Key Features
• SCXI High-Voltage Analog Bus (HVAB) built-in; supports external SCXI Low-Voltage and High-Voltage Analog Bus connectors
• Interoperable with 5 V and universal PXI-compatible products and standard CompactPCI products
• SCXI module support: multiplexing, linearization, filtering, isolation, amplification, and switching
• System status indicators: Power LED, SCXI subsystem power LED, POWER OK LED, and DRIVE LED (with controller)
– Typical Applications
• Data acquisition with signal conditioning
• Precision analog and digital measurements requiring low-noise environments
• Automated test systems combining PXI module density with SCXI module flexibility
• Multi-channel multiplexing and signal routing applications
– Compatibility & Integration
Backplane design integrates PXI and SCXI subsystems with 9-pin D-SUB and auxiliary I/O connectors. Supports both benchtop and rack-mount configurations without additional interface hardware.