The NI PXI-6115 S Series is a 12-bit multifunction DAQ module for PXI systems delivering simultaneous analog acquisition across four channels at 10 MS/s per channel. Dedicated ADCs per input channel ensure accurate transient and frequency measurements with minimal crosstalk. The module supports eight input ranges from ±0.2 V to ±42 V and includes software-configurable antialiasing filters at 50 kHz and 500 kHz (3-pole Bessel), with bypass capability. AC/DC coupling is selectable per channel. Beyond analog input, the PXI-6115 integrates two analog output channels (4 MS/s single-channel, 2.5 MS/s dual-channel), 8 digital I/O channels, and two 24-bit counters/timers. Onboard memory options of 32 MS or 64 MS enable extended capture of high-bandwidth signals. Analog and digital triggering, combined with RTSI and PXI trigger bus synchronization, support multi-device configurations. The module operates in hybrid-slot-compatible PXI systems and standard PXI slots.
Technical Specifications
• Analog Inputs: 4 channels, 12-bit resolution, 10 MS/s simultaneous sampling, ±0.2 V to ±42 V (8 ranges), AC/DC coupling per channel, dedicated ADCs
• Antialiasing Filters: 50 kHz and 500 kHz (3-pole Bessel), software-configurable, bypassable
• Analog Outputs: 2 channels, ±10 V range, 4 MS/s single-channel or 2.5 MS/s dual-channel update rate
• Digital I/O: 8 channels
• Counters/Timers: 2 channels, 24-bit resolution
• Onboard Memory: 32 MS or 64 MS
• Triggering: Analog and digital
• Synchronization: RTSI or PXI trigger bus; PFI lines for signal routing
– Key Features
• Per-channel ADC architecture eliminates sampling skew across all four inputs
• Eight selectable input ranges accommodate signals from millivolt to multi-ten-volt levels
• Input impedance optimized for 20 V and 42 V ranges to preserve high-frequency bandwidth
• Extended onboard memory supports prolonged high-bandwidth capture without external storage
– Typical Applications
• Multi-channel transient and waveform acquisition
• Frequency-domain signal analysis requiring simultaneous sampling
• PXI-based automated test systems with synchronized measurements
– Compatibility & Integration
• Hybrid-slot-compatible: operates in PXI Express hybrid slots and standard PXI slots
• NI-DAQmx driver with configuration utility
• Compatible with parallel-mode SCXI modules (NI-DAQmx 7.4 or later)
• Dimensions: 6.3 in. × 3.9 in. (16 cm × 10 cm)
• Operating temperature: 0 °C to 50 °C; storage: -20 °C to 70 °C
• Recommended warm-up time: 15 minutes