The NI PXIe-1075 is an 18-slot PXI Express chassis engineered for high-speed test and measurement systems requiring extensive channel density and data streaming capability. It delivers up to 4 GB/s total system bandwidth with dedicated 1 GB/s per-slot performance across PXI Express modules, supported by a backplane compliant with PXI-5 and PXI specifications. The chassis accommodates one system timing slot, eight PXI Express peripheral slots, eight hybrid peripheral slots for mixed PXI/PXI Express module deployment, and one system controller slot with three expansion positions.
Technical Specifications
Slots and Architecture
• 18-slot configuration: 1 system timing slot, 8 PXI Express peripheral slots, 8 hybrid peripheral slots, 1 system controller slot with 3 expansion positions
• Per-slot PXI Express bandwidth: up to 1 GB/s dedicated (x4 PCIe, single direction)
• Total system bandwidth: up to 4 GB/s
Electrical
• Input voltage: 100–120 VAC, 220–240 VAC
• Operating voltage: 90–120 VAC, 200–240 VAC
• Maximum total usable power: 791 W
• Maximum slot current: 45 A
• Power per slot: 140 W (system), 38.25 W (peripheral)
• Power supply: universal AC input with automatic voltage/frequency ranging; field-replaceable shuttle with over-current protection via push-reset circuit breaker
• Remote power inhibit and monitoring via D-SUB 9-pin connector
Timing and Synchronization
• PXI modules: 10 MHz reference clock (PXI_CLK10), PXI trigger bus, PXI star trigger
• PXI Express modules: 100 MHz reference clock (PXIe_CLK100), SYNC 100 signal, differential star trigger
• PXI_CLK10 specifications: maximum slot-to-slot skew 500 ps; accuracy ±25 ppm maximum
Environmental
• Operating temperature: 0–55 °C with full power and cooling to all slots, no derating
– Key Features
• High-bandwidth PXI Express backplane supporting mixed module topologies
• Field-replaceable power supply shuttle for reduced mean time to repair
• Dual timing infrastructure for legacy PXI and modern PXI Express synchronization
• Extended ambient temperature range with unrestricted power delivery
– Typical Applications
• Multi-channel data acquisition and streaming systems
• High-speed automated test equipment (ATE) platforms
• Real-time signal processing and measurement
– Compatibility & Integration
Accepts PXI, PXI Express, and hybrid-compatible CompactPCI modules across dedicated and hybrid peripheral slots. Backplane compliance with PXI-5 and base PXI specifications enables heterogeneous module integration within single chassis.