The NI SH96-96 Cable (183228-01) is a 1-meter shielded cable assembly that interconnects National Instruments test and data acquisition devices via dual 96-pin DIN connectors. The cable’s grounded outer shield minimizes electromagnetic interference, maintaining signal integrity across industrial measurement systems. Qualified for operation from 0 °C to 55 °C and non-operating storage to –40 °C, it withstands 30 g peak shock and random vibration to 0.3 grms, meeting MIL-PRF-28800F environmental standards.
Technical Specifications
• Connectors: 96-pin DIN male to 96-pin DIN female
• Length: 1 meter (3.3 ft)
• Shielding: Yes; outer shield connected to earth ground
• Maximum Working Voltage: 60 VDC (any pin to any pin)
• Current Capacity (PWR/ISO_GND pins): 250 mA
• Current Capacity (I/O pins): 50 mA
• Wire Gauge (PWR/ISO_GND): 22 AWG (7/30 stranded, 0.326 mm²)
• Wire Gauge (I/O pins): 28 AWG (7/36 stranded, 0.081 mm²)
• Operating Temperature: 0 °C to 55 °C
• Storage Temperature: –40 °C to 71 °C
• Operating Humidity: 10% to 90%, noncondensing
• Operating Shock: 30 g peak, half-sine, 11 ms pulse
• Operating Vibration: 5 Hz to 500 Hz, 0.3 grms
– Key Features
• Multi-gauge conductors optimize signal and power distribution
• Grounded shield construction suppresses EMI in high-noise environments
• Rated for sustained industrial shock and vibration exposure
• Compliant with MIL-PRF-28800F Class 2 and Class 3 specifications
– Typical Applications
Signal distribution in modular test systems, SCXI-based data acquisition, PXI strain and temperature measurement, and VXI digital I/O expansion.
– Compatibility & Integration
Works with NI VXI-DIO-128, TBX-96 and TBX-1303 terminal blocks, SCXI modules (SCXI-1100, SCXI-1181, SCXI-1102), and PXI modules including PXIe-4339 and compatible PXI strain/bridge and temperature input modules.