Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Service & Repair of Agilent 86142B Optical Spectrum Analyzer OSA

SKU: 86142BCategories: OSA Repair
Brand: Agilent
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

Service and repair for the Agilent 86142B Optical Spectrum Analyzer (OSA). Ensures your OSA is functioning to original specifications, with comprehensive diagnostics and component-level repair. Calibration and performance verification included.

Request CalibrationRequest Repair
Product Starting From:

$100.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote 86142B
Equipment info

Agilent 86142A & 86142B Optical Spectrum Analyzer – Expert Service, Precision Repair & NIST-Traceable Calibration

We provide professional repair, maintenance, and calibration services for both the Agilent 86142A and 86142B Optical Spectrum Analyzers (OSA) — high-performance instruments widely used in DWDM, photonics, and fiber optic test environments. Designed for high dynamic range and precise wavelength measurements across a broad spectrum, these analyzers are essential tools for R&D labs, network manufacturers, and optical component testing. Our skilled technicians specialize in diagnosing and restoring these units to factory-level accuracy using advanced tools and procedures.


Full-Service Process – From Diagnosis to Certified Calibration

Thorough Diagnostics & Functional Testing
Each incoming 86142A or 86142B is subjected to a full diagnostic evaluation. We verify:

  • Wavelength accuracy over the 600–1700 nm range

  • Optical power readings and linearity

  • Trace repeatability, span sweep, and resolution bandwidth

  • Input port condition and optical alignment

  • Grating motor performance and stability

  • Front panel and display functionality

Advanced tunable lasers and calibrated reference sources are used to simulate real test conditions and capture any irregularities or failures.

Typical Problems We Repair

  • Loss of optical signal or degraded sensitivity

  • Inaccurate or drifting wavelength measurement

  • Internal grating assembly failure or misalignment

  • Burnt or worn fiber input connectors (FC/APC, SC/APC)

  • Boot-up issues, firmware freezes, or error codes

  • Damaged front panel knobs, buttons, or displays

  • Power supply instability or noisy internal fans

Component-Level Electrical & Optical Repair
We perform deep-level circuit board troubleshooting to repair or replace failed ICs, capacitors, relays, sensors, and voltage regulators. Optical assemblies are cleaned, re-aligned, and re-centered using factory-grade alignment protocols to recover signal integrity and trace stability.

Monochromator & Grating Alignment
We precisely align the internal monochromator, stepper motors, and grating control assemblies to restore optimal scan accuracy and noise floor. This ensures proper spectrum trace, peak detection, and consistent readings across sweeps.

Self-Test Diagnostics & Firmware Validation
Our repair process includes running full internal diagnostics and checking firmware integrity. Where supported, firmware is updated to improve performance and resolve legacy bugs.

NIST-Traceable Final Calibration
All units receive a certified calibration using NIST-traceable reference sources, which includes:

  • Wavelength accuracy verification with standard lasers

  • Optical power level accuracy testing

  • Noise floor and RBW validation

  • Sweep speed and span verification
    A calibration certificate is provided with detailed before/after performance metrics.


Why Choose Us for 86142A/B Repair?

  • Extensive experience with Agilent / Keysight Optical Spectrum Analyzers, including 86140A/B, 86141B, and other 86100-series models

  • Fast turnaround time – typical service completed within 1–3 business days

  • High repair success rate, even with older or non-functional units

  • Full service warranty and 15-day Right of Return

  • Global shipping support and professional-grade packaging

  • Multiple payment options: PayPal, credit card, ACH, wire


Suitable for:

  • Labs needing urgent repair of in-use 86142A or 86142B units

  • Companies with aging equipment experiencing performance degradation

  • Buyers of used OSAs needing restoration and certification

  • Service teams requiring repeatable, traceable calibration results


Get Your Agilent 86142A or 86142B Repaired by Experts

Whether your Agilent 86142A or 86142B Optical Spectrum Analyzer is showing signs of optical drift, startup errors, reduced sensitivity, or full hardware failure, we have the tools and expertise to restore it. Our blend of technical knowledge, fast service, and accurate calibration ensures your analyzer is ready for high-performance operation.

Request a quote today and let us handle the complete service lifecycle of your 86142A or 86142B unit.

MPN

86142B

Brand Name

Agilent

You May Also Like

Can't Find The Right Product? Contact Us.