The Sigma Systems TP781 Thermal Platform with Controller is a precision temperature-forcing system for component characterization, quality assurance, and environmental stress screening. It maintains controlled thermal environments suitable for low-profile RF devices and high-density power components including IGBTs and MOSFETs. The system combines a compact 11″ × 11″ platform with an advanced TS Series controller, delivering rapid thermal transitions and accurate temperature control in laboratory and production settings.
Technical Specifications
Thermal Platform (TP781)
• Temperature Range: -100°C to +200°C (standard); -165°C to +250°C (optional LN2 extended)
• Cooling Rate: 39°C to 83°C per minute
• Heating Rate: 17°C to 61°C per minute
• Working Surface: 11″ × 11″ precision ground, hard anodized aluminum
• Heating Power: 2700 Watts
• Optional customization: adapter plates, hole patterns, drill masks, drilled/tapped holes with stainless steel inserts, extra plate thickness (may reduce ramp rate ~15%)
Controller (TS Series)
• Temperature Measurement Range: -210°C to 680°C
• Accuracy: ±1.0°C
• Resolution: 0.1°C full scale
• Sensor Inputs: RTD (500 Ohm 2-wire or 100 Ohm 3-wire), Thermocouple Type K
• Control Modes: PID, Dual Loop, settable DUT control
• Display: 5.7″ color touch-screen with real-time graphing and data logging
• Communications: Ethernet 10/100, Telnet, HTML Web Server, USB 2.0; optional RS232 and IEEE-488 GPIB
• Power: 100–250 VAC, 50/60 Hz, up to 30 A
– Key Features
• Advanced fail-safe protection: independent fail-safe module (optional), bi-metal thermostat, precision electronic systems
• Comprehensive diagnostics: runtime hours, valve activation counts, enclosure temperature monitoring, system performance logging
• Multi-sensor compatibility with flexible control algorithms for precise DUT characterization
• Compliance: CE, RoHS, designed to meet UL 61010
– Typical Applications
RF device testing, IGBT and MOSFET characterization, environmental stress screening, quality assurance validation.
– Compatibility & Integration
Controller supports Sigma C, CC3, CC3.5, C4, and C5 functionality and command sets. Optional dry nitrogen purge eliminates moisture and oxygen from test environments.