The Sorensen DCS80-37 is a 3 kW programmable DC power supply delivering 0–80 VDC at 0–37 A for demanding research, development, and industrial testing applications. This low-profile unit combines high power density with precise voltage and current control, automatic CV/CC mode crossover, and exceptional line and load regulation (0.1% each). The 2960 W output integrates remote sensing, multiple programming interfaces, and robust thermal management in a compact 33 lb chassis.
Technical Specifications
• Output: 0–80 VDC, 0–37 A (2960 W maximum)
• Regulation: Line 0.1%, Load 0.1%
• Ripple: 80 mV RMS / 440 mV peak-to-peak
• Meter Accuracy: ±1% of full scale + 1 count
• Voltage Resolution: 0.02%
• Programming Accuracy: ±1% (remote analog, voltage and current)
• Transient Response: Recovers within 1 ms to 1% steady-state (70–100% load step)
• Remote Sensing: Up to 1 V per lead compensation
• Maximum Voltage to Ground: 150 VDC
– Key Features
• Front-panel 10-turn potentiometers with simultaneous voltage/current display
• Automatic CV/CC mode crossover with fast transient response
• TTL-compatible remote start/stop and interlock inputs (12–250 VAC / 12–130 VDC)
• Status indication for overtemperature, OVP, remote programming, and operating mode
• Internal fan with over-temperature shutdown protection
– Interfaces & Programming
• Analog Control: Isolated analog voltage, current, and OVP programming (optional)
• Digital: IEEE-488/RS-232 interface (Option M9C, 12-bit) or LXI Ethernet/RS-232 (Option M130, 16-bit)
• Software Support: LabVIEW drivers (M9C/M85), IVI-com (M130), LabWindows CVI (M9C)
– Input & Environmental
• Input: 190–250 VAC three-phase (47–63 Hz) or 200–250 VAC single-phase (47–63 Hz); max 2.5 kW single-phase
• Operating Temperature: 0°C to 50°C
• Storage Temperature: −55°C to 85°C
• Weight: Approximately 33 lbs (15 kg)