The Sorensen DHP80-62-M2-M9D is a programmable DC power supply delivering 5 kW across 0–80 V and 0–62 A. Built for research, development, and industrial test environments, it combines precise voltage and current control with three operational modes: constant voltage, constant current, and constant power with automatic crossover. The M2 input option specifies 432–528 VAC, 47–63 Hz, 3-phase, 3-wire plus ground configuration (Delta or Wye compatible). The M9D option adds IEEE-488.2 digital interface capability for remote automation and control.
Technical Specifications
Output Ratings
• Voltage: 0–80 V DC
• Current: 0–62 A DC
• Power: 5 kW
Input Power (M2)
• Voltage: 432–528 VAC, 47–63 Hz
• Configuration: 3-phase, 3-wire plus ground (Delta or Wye)
• Power Factor: Minimum 0.72
Voltage and Current Regulation
• Line regulation (voltage): ±0.1% of rated output
• Line regulation (current): ±0.5% of rated output
• Load regulation (voltage): ±0.1% of rated output
• Load regulation (current): ±0.5% of rated output
Output Quality
• Ripple at 80 V: 45 mVp-p
• Ripple at 20–60 V: 30 mVp-p
• Transient response: 2 ms to steady state
• Stability: ±0.05% of maximum rating per 8 hours (after 30-minute warm-up at fixed conditions)
• Temperature coefficient (voltage set point): 0.02%/°C of maximum rating
• Temperature coefficient (current set point): 0.03%/°C of maximum rating
Programming and Control
• Modes: Constant voltage, constant current, constant power with automatic crossover
• Auto-step programming: Up to 9 steps, 1 second to 99,999 seconds per step (27.7-hour maximum program duration)
• Voltage programming resolution: 0.3% of full scale
• Current programming resolution: 0.3% of full scale
• Voltage accuracy: 0.10% + 0.3% of maximum output
• Current accuracy: 0.3% + 0.3% of maximum output
• Voltage readback: 0.10% + 0.3% of full scale
• Current readback: 0.3% + 0.3% of full scale
• Overvoltage protection set: 0.5% of full scale (110% of maximum output voltage)
Protection and Sensing
• Remote sense terminals provided; maximum 3% voltage drop per line or 2 V
– Key Features
• Second-generation control technology for enhanced programmability
• Automatic mode crossover between constant voltage, constant current, and constant power
• Extended auto-step sequences up to 27.7 hours total duration
• Remote sensing for load compensation
– Typical Applications
Suited for demanding electrical testing, product qualification, system integration development, and long-duration burn-in cycles requiring stable mid-range DC power with repeatable multi-step operation.
– Compatibility & Integration
M9D option provides IEEE-488.2 bus interface for digital control and automated test system integration.