The TDK-Lambda / Nemic-Lambda GEN 40-38-IEMD is a 1520 W programmable DC power supply engineered for OEM, industrial, and laboratory applications requiring high power density and flexible control. Operating from 0 to 40 Vdc and 0 to 38 A with 88% typical efficiency, this unit delivers clean power with 0.008 Vrms voltage ripple and 0.095 Arms current ripple across the 5 Hz to 1 MHz bandwidth. The supply accepts a wide AC input range of 85 to 265 Vac (47 to 63 Hz, single-phase) and features active power factor correction at 0.99 typical at full load. Built on modular and SMT technology, the GEN 40-38-IEMD integrates CV/CC auto-crossover control with extensive digital and analog interfaces, enabling standalone operation or integration into multi-unit systems via active current sharing or daisy-chain addressing.
Technical Specifications
• Output Voltage: 0 to 40 Vdc
• Output Current: 0 to 38 A
• Rated Output Power: 1520 W
• Efficiency: 88% typical
• Voltage Ripple Noise: 0.008 Vrms (5 Hz to 1 MHz)
• Current Ripple Noise: 0.095 Arms (5 Hz to 1 MHz)
• AC Input: 85 to 265 Vac, 47 to 63 Hz, single-phase
• Power Factor Correction: 0.99 typical at full load
• CV/CC Auto-Crossover: Standard
• Dimensions: 422.8 mm W × 43.6 mm H × 432.8 mm D
• Weight: Approximately 8500 g
• Form Factor: 1U Rack Mount / Benchtop
– Key Features
• RS-232/RS-485 interface standard; optional IEEE (GPIB/SCPI), LAN (LXI Class C), and USB
• Analog programming: user-selectable 0–5 V or 0–10 V via DIP switches; optional isolated 4–20 mA
• Remote ON/OFF and Enable/Disable with independent control
• Four-digit LED meters for voltage and current readout
• Adjustable Over-Voltage Protection, Under-Voltage Limit, and Current Foldback
• Front panel encoders with selectable fine (~6 turns) or coarse (~30 turns) adjustment
• Front panel lockout and output preview with output OFF
• Last Setting Memory: retains output, mode, protection, and baud rate after power loss
• Safe Re-Start: user-configurable return to previous settings or zero output
• Up to 31 units addressable in daisy chain via RS-485
• Up to four units in parallel operation with active current sharing
– Typical Applications
OEM integration, industrial test and burn-in, laboratory bench testing, automated test equipment (ATE), and power conversion R&D.
– Compatibility & Integration
Standard RS-232/RS-485 connectivity; optional GPIB, LAN, and USB for multi-platform integration. Daisy-chain capability supports distributed control of up to 31 units. Parallel-capable design enables current multiplication and redundancy configurations.