The Yokogawa 701947 is an isolated passive voltage probe engineered for high-voltage measurements up to ±1000 V with 200 MHz bandwidth and 1.2 ns rise time. Electrical isolation eliminates ground loops and reduces noise in sensitive measurement environments. The 100:1 attenuation ratio and 100 MΩ input impedance deliver clean, accurate signals across DC to 200 MHz. Built with an isolated BNC connector and 1.5 m cable, this probe integrates directly with Yokogawa’s isolated-input ScopeCorder modules for real-time data acquisition in demanding industrial and aerospace applications.
Technical Specifications
• Attenuation Ratio: 100:1
• Bandwidth: DC to 200 MHz (-3 dB)
• Rise Time: 1.2 ns maximum
• Input Resistance: 100 MΩ
• Input Capacitance: 7 pF
• Probe Length: 1.5 m
• Connector Type: Isolated BNC
– Key Features
• High-Voltage Measurement Capability: ±1000 V (DC + AC peak) between shield and ground (CAT II); ±3540 V (DC + AC peak) between tip and ground (CAT I)
• Safety Rating: EN61010-031:2002, CAT I and II
• Galvanic Isolation: Eliminates measurement uncertainty from ground potential differences
• Fast Transient Response: 1.2 ns rise time captures rapid switching events in power electronics
• Included Accessories: B8073ZF Safety Plug-On Clip (high-side) and B8074ZG Safety Clip Lead (low-side)
• Operating Range: 5 to 40°C, 20 to 80% RH (non-condensing); storage to -10 to 70°C
• Altitude Rating: 2000 m or less
– Typical Applications
Power electronics, motor drives, power conversion, semiconductor testing, automotive systems, renewable energy, industrial control, appliances, data centers, aerospace, optical communications, and quantum computing research.
– Compatibility & Integration
Designed for Yokogawa DL750, DL750P, SL1400, and SL1000 ScopeCorder isolated-input modules. Connector type and isolation architecture ensure plug-and-play integration with compatible instruments.