The HP/Agilent 6032A is a 1000 W autoranging DC power supply delivering 0–60 V and 0–50 A output. Its autoranging topology maximizes available power across the voltage-current operating envelope, eliminating the need for multiple supplies and reducing ATE rack footprint. The unit combines precision analog control with full SCPI programmability, making it suitable for automated test systems, product development, and burn-in applications requiring stable, regulated power delivery.
Technical Specifications
Output Ratings
• Voltage: 0–60 V
• Current: 0–50 A
• Power: 1000 W
Programming & Readback Accuracy (25°C ±5°C)
• Voltage programming: ±0.035% of setting + 40 mV
• Current programming: ±0.2% of setting + 85 mA
• Voltage readback: ±0.08% of setting + 20 mV
• Current readback: ±0.36% of setting + 35 mA
Output Ripple & Noise (20 Hz to 20 MHz)
• Voltage RMS: 8 mV
• Voltage peak-to-peak: 40 mV
• Current RMS: 25 mA
– Key Features
• Autoranging output for maximum power at any voltage–current operating point
• Analog and resistance control of voltage and current
• Over-voltage protection (OVP) and foldback current limiting
• Built-in measurement functions
• Front-panel annunciator LEDs for status and error indication
– Typical Applications
• Automated test equipment (ATE) systems
• Product development and characterization
• Burn-in and reliability testing
• Device under test (DUT) power delivery requiring precision and protection
– Compatibility & Integration
Programming & Control
• GPIB (IEEE-488) interface for remote programming
• SCPI command support
• VXIplug&Play driver compatibility
• Serial link for daisy-chaining up to 16 units on a single GPIB address
Input Power
• 87–106 VAC, 48–63 Hz
• 104–127 VAC, 47–63 Hz
• 191–233 VAC, 48–63 Hz
• 209–250 VAC, 48–63 Hz
Physical & Environmental
• Dimensions: 6 × 17 × 20 inches
• Weight: 35 lbs
• Operating humidity: Maximum 95% RH
• Altitude: Up to 2000 m
• Safety Class 1 with protective earth terminal