The Keysight 6811B AC Power Solution is a benchtop AC source and power analyzer that generates and measures AC and DC power with integrated waveform synthesis and harmonic analysis. It operates as both a programmable power amplifier and arbitrary waveform generator, delivering up to 375 VA at 300 Vrms with 3.25 A RMS output and 40 A peak current capability. The instrument generates sinusoidal, square, triangular, clipped sine, and user-definable waveforms across 45 Hz to 1 kHz, with full control over voltage slew, frequency slew, and output impedance. Built-in measurement capabilities eliminate the need for separate test equipment: voltage and current analysis (RMS, DC, AC+DC), real/apparent/reactive power, harmonic content to the 50th harmonic, THD, and peak detection. Measurement accuracy includes RMS voltage at 0.03% + 100 mV (35–100 Hz) and RMS current at 0.05% + 10 mA (45–100 Hz). The 6811B also provides triggered digitized acquisition of voltage and current waveforms. DC output reaches ±425 V at 2.5 A (285 W). Line regulation is 0.1% of full scale; load regulation 0.5%. Output noise measures −60 dB relative to full scale (20 kHz to 10 MHz). The instrument accepts 100–240 VAC universal input and connects via GPIB (HP-IB) or RS-232 with SCPI command support.
Technical Specifications
• AC Output: 375 VA maximum; 300 Vrms; 3.25 A RMS; 40 A repetitive and non-repetitive peak; crest factor 12
• DC Output: 285 W; ±425 V; 2.5 A
• Frequency: 45 Hz to 1 kHz AC; DC capable
• Waveforms: Sinusoidal, square, triangular, clipped sine, user-definable
• Voltage Measurement: RMS, DC, AC+DC; accuracy 0.03% + 100 mV (35–100 Hz) or 0.15% + 0.3 V (45–100 Hz)
• Current Measurement: RMS, DC, AC+DC; accuracy 0.05% + 10 mA (45–100 Hz)
• Power Analysis: Real, apparent, reactive power; harmonic content to 50th; THD
• Line Regulation: 0.1% of full scale
• Load Regulation: 0.5% of full scale
• Output Noise: −60 dB relative to full scale (20 kHz to 10 MHz)
– Key Features
• Programmable voltage and frequency slew control
• Arbitrary waveform generation including distorted power conditions
• Peak voltage and current measurement with triggered acquisition
• Harmonic amplitude and phase analysis
– Typical Applications
• AC-powered device and system validation
• Power condition simulation (sags, dropouts, brownouts)
• RTCA-D0160 and MIL-STD-704 testing
– Compatibility & Integration
• GPIB (HP-IB) and RS-232 interfaces
• SCPI programming language
• VXI plug&play drivers, Keysight VEE, NI LabVIEW compatible
• Universal AC input 100–240 VAC, 50/60 Hz