The Lambda / TDK / EMI EMS20-250-2-D-RSTL is a power supply unit designed to provide reliable and efficient power conversion. It features a robust design and is suitable for various industrial applications. It offers stable output and protection features.

Request CalibrationRequest Repair
Product Starting From:

$2,800.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote EMS20-250-2-D-RSTL
Equipment info

The Lambda / TDK / EMI EMS20-250-2-D-RSTL is a 5 kW switch-mode AC-to-DC power supply engineered for high-current, low-voltage industrial applications. It delivers 0–20V at 0–250A with constant current/constant voltage regulation and automatic crossover. The unit operates from three-phase AC input (190–250 VAC, 47–63 Hz, 23A) and includes front-panel adjustable overvoltage protection, thermal shutdown, and soft-start circuitry. Fully programmable via analog control or optional RSTL (RS232/IEEE 488) digital interface, it supports master-slave configuration for series and parallel operation.

## Technical Specifications

• Output Power: 5 kW
• Output Voltage: 0–20 V
• Output Current: 0–250 A
• Regulation (Voltage Mode): <0.1% of maximum output voltage for 100% load change
• Regulation (Current Mode): <0.1% of maximum output current for 100% load change
• Output Ripple: 75 mV RMS (approximately 30% of P-P carrier ripple)
• Transient Response: 650 microseconds for 30% load step below 20 V
• Stability: ±0.05% maximum deviation over 8 hours at constant line, load, and temperature
• Temperature Coefficient (Voltage): 0.02% per 1°C of rated output voltage
• Temperature Coefficient (Current): 0.03% per 1°C of rated output current
• Input Frequency: 47–63 Hz

## Key Features

• Dual-mode regulation with automatic crossover between CC and CV
• Programmable via analog voltage/current inputs or RSTL digital interface
• Built-in overvoltage protection (front-panel adjustable)
• Thermal protection and soft-start standard
• Digital panel meters for real-time monitoring
• External air-cooled design
• Rack-mountable chassis (19 in × 25 in × 5.5 in, 56 lb)

## Typical Applications

• Semiconductor processing and equipment
• Medical device manufacturing
• Scientific research laboratories

## Compatibility & Integration

• Master-slave configuration for series/parallel stacking
• RSTL interface supports RS232 and IEEE 488 protocols
• Three-phase input options: 190–250 VAC (23A), 342–418 VAC, 360–440 VAC, 374–456 VAC (Five Wire configurations)

MPN

EMS20-250-2-D-RSTL

Frequency Range

47–63 Hz

Voltage / Current Range

0–20 V, 0–250 A; Input: 190–250 VAC 3-phase, 23 A

Brand Name