The National Instruments PXI-1011 is a hybrid chassis that integrates a 4-slot PXI subsystem with an 8-slot SCXI subsystem into a single instrument platform. It accepts embedded controllers or MXI-3 interfaces in the PXI section and supports signal conditioning modules in the SCXI section, enabling integrated data acquisition, signal switching, and analog/digital conditioning. The chassis operates at up to 333 kS/s and delivers 140 W maximum useable power to PXI modules. Its dual-backplane architecture—PXI with reference clock, trigger bus, and star trigger capabilities, plus SCXIbus with analog, digital, and timing interconnect—supports modular expansion for DIO, MIO, and instrument modules. CompactPCI interoperability permits installation of both PXI and CompactPCI modules. The chassis measures 17.6 × 17.3 × 7.0 inches, weighs 20 lbs, and mounts on benchtops or in standard 19-inch racks with available brackets. SCXI daisy-chaining extends conditioning channel capacity. Input power spans 100–240 VAC, 47–440 Hz with 5 A circuit breaker protection. Operating range is 0–50 °C; storage is –20–70 °C. Note: This product has been announced obsolete by National Instruments but may remain available through third-party vendors.
Technical Specifications
• PXI subsystem: 4 slots
• SCXI subsystem: 8 slots
• Maximum sampling rate: 333 kS/s
• PXI maximum useable power: 140 W
• AC input voltage: 100–240 VAC
• AC input frequency: 47–440 Hz
• Overcurrent protection: 5 A circuit breaker
• Dimensions: 17.6 × 17.3 × 7.0 inches
• Weight: 20 lbs
• Operating temperature: 0–50 °C
• Storage temperature: –20–70 °C
– Key Features
• Integrated PXI-SCXI interconnection allows DAQ/DMM module placement in PXI slot 4 for direct SCXI control without external cabling
• Full PXI backplane compliance with reference clock, trigger bus, star trigger, and local bus
• Complete SCXIbus implementation: analog, digital, and timing buses for intermodule communication and integrated analog multiplexing
• Overvoltage protection and integrated overcurrent control
• Dual-mount capability: benchtop or 19-inch rack installation with adjustable front-panel depth brackets
• SCXI daisy-chaining support for signal-conditioning expansion
– Compatibility & Integration
• Accepts embedded controllers or MXI-3 interfaces in PXI section
• Compatible with PXI and CompactPCI modules per PXI specification interoperability
• Integrates digital I/O, multifunction I/O, and computer-based instrument modules
• Supports SCXI signal conditioning modules for analog/digital input conditioning and isolation