Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Philips PM3585/90

SKU: PM3585/90Categories: Logic Analyzers
Brand: Philips
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Philips PM3585/90 is a logic analyzer that allows you to capture, display, and analyze digital signals. It helps in debugging and verifying digital circuits and systems.

Request CalibrationRequest Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote PM3585/90
Equipment info

The Philips PM3585/90 is a 90-channel logic analyzer engineered for digital signal analysis, debugging, and verification of digital circuits and systems. Its Dual Analysis Per Pin (DAPP) architecture enables simultaneous correlated state and timing analysis on each channel, allowing a single acquisition to capture both timing and state data without dual probing or repeated measurements.

Technical Specifications

• Channels: 90 dual-analysis channels
• Timing Logic Analysis: 200 MHz maximum speed; 2K-sample acquisition memory supporting TimeWord, tw7, twg, Glitch, and Edge capture
• State Logic Analysis: 50 MHz maximum speed; 2K-sample acquisition memory with support for synchronous and asynchronous trigger words; up to 4 simultaneous state clocks
• Acquisition Memory: 2K samples (assignable to timing only, timing + glitch, timing + state, or state only)
• CPU: 68070 16/32-bit processor
• Display: Nine-inch white phosphor CRT, high-resolution
• Storage: 3.5-inch micro floppy disk drive
• Weight: 28 lbs

– Key Features

• Simultaneous correlated state and timing analysis per pin eliminates need for dual acquisitions
• Front-mounted BNC connections and pod connectors (16 signals per pod) for flexible signal routing
• Integral keypad and rotary knob interface
• Rear-mounted BNC connections for trigger signal input and output
• External video output port

– Interfaces & Peripherals

• Pod connectors for multi-signal acquisition
• Centronics printer interface for hardcopy output
• RS-232-C serial ports for peripheral communication
• Optional IEEE communication interface (PF 8653/20)
• 3.5-inch micro floppy disk for setup and data storage

– Typical Applications

The PM3585/90 serves R&D, manufacturing, service, and educational environments where simultaneous timing and state analysis accelerates debug cycles and verification workflows.