The Sorensen DHP25-265 is a 25 kW DC power supply designed for industrial test, burn-in, and laboratory environments requiring precise voltage and current control. Operating from 0–25 V and 0–265 A, it delivers stable, accurate power across constant voltage, constant current, and constant power modes. Output stability reaches ±0.05% of full scale after an 8-hour warm-up, with line and load regulation at 0.1% and ripple under 0.01% p-p. The unit supports three-phase input (Delta or Wye) and integrates analog, IEEE-488.2, and RS-232 control interfaces for seamless integration into automated test systems.
Technical Specifications
• Output Power: 25 kW
• Voltage Range: 0–25 V
• Current Range: 0–265 A
• Output Stability: ±0.05% of full scale (±0.05% of set point after 8-hour warm-up)
• Line Regulation: 0.1% of maximum rated output
• Load Regulation: 0.1% (voltage), 0.5% (current) of maximum rated output
• Ripple and Noise: < 0.01% p-p; 10 mV typical at rated load
• Temperature Coefficient: 0.02%/°C (voltage); 0.03%/°C (current)
• Transient Response: 2 ms to steady state (within 2% of Vmax) at 30% step load
• Operating Modes: Constant Voltage (CV), Constant Current (CC), Constant Power (CP)
• Input: Three-phase, 3-wire plus ground (Delta or Wye); 0.72 minimum power factor
• Voltage Programming Resolution: 0.3% of full scale
• Voltage Programming Accuracy: 0.10% + 0.3% of maximum output voltage
• Voltage Readback Resolution/Accuracy: 0.3% of full scale; 0.10% + 0.3% of full scale output
– Key Features
• Programmable voltage, current, and power set points and limits
• Auto-sequence programming with up to 9 configurable steps (1 second to 99,999 seconds per step; maximum 27.75 hours total)
• Front panel keypad for local operation
• Remote on/off control via contact closure (6–120 VDC, 12–240 VAC, TTL/CMOS)
• Output voltage and current monitoring (0–10 V)
• OVP limit setting and summary fault status
• Remote sense terminals to compensate for output lead voltage drops (maximum 3% line drop)
– Typical Applications
Burn-in testing, industrial load simulation, electrochemical research, materials processing, and high-current component qualification.
– Compatibility & Integration
Standard analog input, IEEE-488.2, RS-232, and isolated analog control interfaces enable integration with test automation platforms and instrumentation systems.