The Tektronix TIVP02L IsoVu probe is a 200 MHz isolated differential probe engineered for high-voltage and high-bandwidth measurement applications. It delivers complete galvanic isolation between measurement systems and the device under test through power-over-fiber technology and an optical analog signal path, enabling accurate differential signal acquisition in environments with extreme common-mode voltages. The Gen 2 design provides a compact form factor suited to power electronics, automotive, and wide bandgap semiconductor characterization.
Technical Specifications
• Bandwidth: 200 MHz
• Rise Time: 2 ns
• Differential Input Voltage Range: ±2500 V
• Common Mode Voltage Range: ±60 kV
• Offset Range: ±2500 V
• Common Mode Rejection Ratio (CMRR): 160 dB DC | 120 dB @ 100 MHz | 80 dB @ 1 GHz
• Input Capacitance: < 2 pF
• Differential DC Gain Accuracy: < 2%
• Switchable Termination: 1 MΩ and 50 Ω (at SMA connector)
• Fiber Cable Length: 10 m
– Key Features
• Complete galvanic isolation via optical signal path and fiber transmission
• MMCX probe tips for optimized bandwidth and CMRR performance
• Probe tip adapter enables connection to standard 0.100" spaced, 0.025" square pins
• Soft carrying case with foam insert and complete accessory kit included
– Typical Applications
• SiC and GaN bridge topologies (half and full bridge)
• Floating measurements in power converters
• Switching power supply and inverter design
• Motor drive characterization
• Power device evaluation and switching transient analysis
• EMI and ESD troubleshooting
• Current shunt measurements
– Compatibility & Integration
Natively optimized for Tektronix 4, 5, and 6 Series MSO oscilloscopes running software version 1.28 or higher. Connection to MSO70000C/DPO70000C and DPO70000SX series requires the TCA-VPI50 adapter.