The Teledyne LeCroy T3AFG350 is a dual-channel Function/Arbitrary Waveform Generator delivering 350 MHz bandwidth with high-fidelity, low-jitter signal generation. Built on proprietary Arbitrary & Pulse techniques, it overcomes traditional DDS limitations when generating arbitrary, square, and pulse waveforms. The instrument combines 20 Mpts memory per channel, 2.4 GS/s sample rate, and 16-bit vertical resolution to support complex electronics testing and design applications requiring versatile, precision signal generation.
Technical Specifications
• Bandwidth: 350 MHz
• Channels: 2 independent channels
• Memory per channel: 20 Mpts
• Sample rate: 2.4 GS/s (with 2× interpolation)
• Vertical D/A resolution: 16 bits
• Output impedance: 100 Ω
• Dynamic range: 80 dB
• Frequency resolution: 1 µHz
• Square wave rise/fall time: 2.4 ns (1 Vpp, 50 Ω load)
• Jitter (rms, cycle-to-cycle): 100 ps (1 Vpp, 50 Ω load, TrueArb mode)
Output voltage capability varies by frequency. At ≤20 MHz: maximum 10 Vpp (50 Ω) or 20 Vpp (high impedance); >20 MHz: maximum 5 Vpp (50 Ω) or 10 Vpp (high impedance). Minimum amplitude: 1 mVpp (50 Ω) or 2 mVpp (high impedance).
– Key Features
• 7 standard waveforms: Sine, Square, Pulse, Ramp, DC, Noise, PRBS
• 196 built-in arbitrary waveforms with user-defined waveform support
• PRBS3 to PRBS32 waveform capability
• Analog modulation: AM, DSB-AM, FM, PM
• Digital modulation: FSK, ASK, PSK, PWM
• Sweep (linear or logarithmic, up/down) and burst modes (N-cycle, gated)
• 10th-order harmonic function
• Built-in high-precision frequency counter (8-digit resolution)
• Waveform combining and channel coupling/tracking
• 4.3-inch TFT LCD touchscreen interface
• USB Host, USB Device (USBTMC), and LAN (VXI-11) connectivity
• Auxiliary modulation input (0 Hz to 50 kHz, 10 kΩ impedance)
• 10 MHz reference clock input/output
– Typical Applications
Arbitrary waveform generation for device characterization, signal integrity testing, modulation analysis, and prototype validation in analog and mixed-signal design workflows.
– Compatibility & Integration
Usb Device (USBTMC) and LAN (VXI-11) enable remote instrument control and data transfer. Frequency counter input and auxiliary I/O support synchronized multi-instrument test setups. Operating temperature: 0 °C to 40 °C. Dimensions: 260.3 mm (W) × 107.2 mm (D) × 295.7 mm (H); net weight: 3.5 kg.