The Acopian P020HP1.5 is a single-output AC-DC power supply engineered for precision voltage and current regulation in laboratory and industrial test environments. This unit delivers 0–20 VDC output at 1.5 mA with exceptional line and load regulation, floating output architecture, and comprehensive short-circuit protection. The supply operates from 105–125 VAC, 50–400 Hz single-phase input (230 VAC option available) and accommodates ambient temperatures from –10 to +60°C without derating.
Technical Specifications
• Input: 105–125 VAC, 50–400 Hz, single phase (optional 210–250 VAC)
• Output: 0–20 VDC, 1.5 mA maximum
• Regulation (Constant Voltage): ±0.05% line, ±0.05% load
• Regulation (Constant Current): ±0.1% line, ±0.1% load
• Current Accuracy: 2% of maximum rated output
• Stability: 0.05% over 8 hours (post 30-minute warm-up)
• Temperature Coefficient: 200 PPM/°C (0.02%/°C typical)
• Efficiency: >70% at full load
• Response Time: <5 mS for 100 µA load step
• Ambient Operating Temperature: –10 to +60°C
• Storage Temperature: –20 to +85°C
• Humidity: 90% relative maximum, non-condensing
– Key Features
• Floating output topology—either terminal may be grounded or elevated to 300 V above ground
• Remote voltage sensing across load as standard
• Soft-start circuit minimizes inrush stress
• Current regulation circuit protects against short circuits, overload, and arcing
• Screw terminal connections: 24" flying lead (high side), 5-way binding post (return), separate AC input strip, pluggable terminal block for auxiliary connections
• Extruded aluminum enclosure, light gray enamel finish
• Threaded mounting holes for RETMA 19" cabinet rack integration or bench mounting
• ISO 9001 certified, TAA compliant
– Typical Applications
Precision test and measurement systems requiring stable, regulated low-current DC power with minimal ripple and excellent transient response. Suitable for sensor excitation, instrumentation calibration, and laboratory apparatus where voltage regulation and load isolation are critical.
– Compatibility & Integration
Available with optional terminal strip cover (suffix M) and 230 VAC input variant (suffix -230). Standard screw terminal interface permits field integration into custom test racks and benchtop setups.