Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Advantest R6246 DC Voltage Current Source

SKU: R6246Categories: Data Acquisition Systems (DAQ)
Brand: Advantest
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

Advantest R6246 DC Voltage Current Source,Stable and precise DC voltage and current source used in calibration, component testing, and automated test systems.

Request CalibrationRequest Repair
Product Starting From:

$4,579.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote R6246
Equipment info

The Advantest R6246 DC Voltage Current Source is a dual-channel Source Measurement Unit (SMU) instrument for precision voltage and current sourcing and measurement. It delivers synchronized generation and measurement across two isolated channels, making it ideal for DC characterization of semiconductors, integrated circuits, and power devices in R&D, component testing, and automated test system environments.

Technical Specifications

Channel A (SMU62-20):
• Source voltage: ±62 V
• Source current: ±20 A
• Source resolution (voltage): 10 µV
• Source resolution (current): 1 nA at 62 µA range
• Measurement resolution (voltage): 1 mV, 1 µV
• Measurement resolution (current): 10 fA, 100 pA at 6 nA range
• Maximum output power: 140 W
• Connectors: Banana

Channel B (SMU220-2):
• Source voltage: ±220 V
• Source current: ±2 A
• Source resolution (voltage): 10 mV
• Source resolution (current): 100 µA at 2 A range
• Measurement resolution (voltage): 1 mV, 1 µV
• Measurement resolution (current): 10 fA, 100 pA
• Maximum output power: 24.2 W
• Connectors: Triax

Measurement Accuracy:
• Voltage accuracy: ±0.01% of setting
• Current accuracy: ±0.01% of setting
• Source accuracy: ±0.03%
• Measurement accuracy: ±0.02%
• Load regulation: ±0.0017% of range or less (4-wire)

– Key Features

• Synchronized dual-channel generation and measurement across isolated channels
• High throughput: 0.8 V/µs at current measurement ranges ≥6 mA
• Range switching without discontinuous output
• Trigger Link Function for automated test sequencing
• Sequence Programming Function for multi-step test execution
• Search Measurement Function for specialized characterization
• Minimum pulse width: 100 µs; minimum step: 700 µs

– Typical Applications

• DC characterization of discrete semiconductors and integrated circuits
• Power device evaluation and testing
• Automated test systems requiring synchronized dual-channel sourcing
• Complex device characterization requiring simultaneous generation and monitoring

– Compatibility & Integration

Channel A uses banana connectors; Channel B uses triax connectors for flexible integration into test fixtures and automated platforms.

MPN

R6246

Voltage / Current Range

±2 A, ±20 A, Channel A: ±62 V, Channel B: ±220 V

Brand Name

Advantest

You May Also Like

Can't Find The Right Product? Contact Us.