The TDK-Lambda EMS200-25-2-D is a 200W DC power supply engineered for laboratory test and burn-in applications. It delivers stable, adjustable DC voltage and current with constant voltage (CV) and constant current (CC) modes featuring automatic crossover. Built-in protection circuits, including overvoltage, overcurrent, and overtemperature safeguards, ensure reliable operation across demanding test environments. The unit accepts single-phase AC input from 85–265 VAC (47–63 Hz) and reaches up to 89% efficiency. Front-panel voltage and current adjustment knobs enable local control, while remote programming via analog resistance, external DC voltage, or external DC current supports automated test sequences. Standard interfaces accommodate integration with external equipment and test systems.
## Technical Specifications
• Output power: 200W at 25V nominal
• Output current: 8A
• Input voltage range: 85–265 VAC, single phase, 47–63 Hz
• Efficiency: Up to 89%
• Line regulation: <0.1% of maximum output voltage
• Load regulation (voltage mode): <0.1% of maximum output voltage for 100% load change
• Load regulation (current mode): <0.1% of maximum output current for 100% load change
• Stability (8-hour): 0.05% under constant line, load, and temperature
• Output ripple and noise: RMS ripple approximately 30% of peak-to-peak carrier ripple
## Key Features
• Constant voltage/constant current control with automatic crossover
• Overvoltage protection (standard for models ≤300 VDC)
• Pulse-by-pulse overcurrent limiting with fast recovery
• Overtemperature protection with LED status indication
• Soft start standard
• Analog resistance, external DC voltage, and external DC current remote programming
## Typical Applications
• Component and system burn-in testing
• Laboratory power sourcing
• Reliability qualification and life testing
## Compatibility & Integration
Remote programming interfaces include analog resistance, external DC voltage, and external DC current inputs. Optional interfaces support USB, RS-232/RS-485, LAN, IEEE 488.2 SCPI, EtherCAT, and Modbus-TCP connectivity.