The TDK-Lambda GEN 60-55 is a 3.3 kW programmable DC power supply delivering 0–60 Vdc at 0–55 A output. Built for industrial, telecom, and test & measurement environments, it combines precise voltage and current regulation with active power factor correction and multiple communication interfaces. The unit operates from three-phase AC inputs (170–265 Vac or 342–460 Vac, 47–63 Hz) with optional single-phase capability, achieving 88% typical efficiency and 0.99 power factor at full load. Voltage ripple noise measures 0.008 Vrms and current ripple 0.1 Arms across the 5 Hz to 1 MHz bandwidth. Housed in a compact 2U rack-mount or bench-top enclosure (423 × 88 × 442.5 mm, 13 kg), the supply includes 16-bit ADC/DAC converters for high-resolution programming and automatic CV/CC mode crossover.
## Technical Specifications
• Output: 0–60 Vdc, 0–55 A (3300 W)
• Voltage ripple noise: 0.008 Vrms (5 Hz–1 MHz)
• Current ripple noise: 0.1 Arms (5 Hz–1 MHz)
• Input voltage: 170–265 Vac three-phase, 47–63 Hz; 342–460 Vac three-phase, 47–63 Hz (480 V model); 170–265 Vac single-phase optional
• Efficiency: 88% typical
• Power factor: 0.99 typical at full load; 0.94 typical at rated load (three-phase 400 VAC)
• Dimensions: 423 mm W × 88 mm H × 442.5 mm D
• Weight: 13 kg
## Key Features
• Automatic CV/CC mode switching
• Adjustable overvoltage protection, undervoltage lockout, and current foldback
• Last-setting memory (non-volatile) for voltage, current, OVP, UVL, foldback, baud rate, and startup mode
• Selectable fine (6 turns) or coarse (30 turns) encoder adjustment
• Front panel lockout to prevent unauthorized changes
• Parallel operation: up to four units with active current sharing and master/slave control
• User-selectable safe restart after power loss
• SMT modular design for reliability
## Compatibility & Integration
• Standard: RS-232, RS-485 (daisy-chain up to 31 units)
• Optional: LAN (LXI Class C), GPIB (IEEE 488.2 & SCPI), USB 2.0, isolated analog (0–5 V or 0–10 V), isolated 4–20 mA current control
• Remote ON/OFF and Enable/Disable functions
• Analog programming: DIP-switch selectable 0–5 V or 0–10 V input