The Lambda/TDK EMI TCR500T10 is a robust power supply designed for various industrial applications. It offers reliable performance and excellent electromagnetic interference (EMI) characteristics. This power supply is engineered to provide stable and efficient power conversion, ensuring optimal operation of connected devices and systems. Its durable construction and advanced features make it suitable for demanding environments where consistent power delivery is crucial.

Request CalibrationRequest Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote TCR500T10
Equipment info

The Lambda/TDK EMI TCR500T10 is a 10 kW industrial power supply engineered for demanding environments requiring stable DC output with exceptional load and line regulation. The unit integrates advanced RFI/EMI filtering and soft-start AC input conditioning to deliver clean, regulated power across a wide range of operating conditions.

Technical Specifications

AC Input
• Input voltage options: 115 VAC, 208/220 VAC, 230 VAC (optional 100 VAC and 200 VAC available)
• Input frequency: 47 to 63 Hz
• Voltage operating range: 105–130 V for 115 V models; 190–253 V for 208/220 V models
• Phase-to-phase voltage balance: ±2% for ripple specification compliance
• Phase rotation sequence: not required
• Soft-start with input SCRs to eliminate inrush current transients
• Current draw at 10 kW: 46 A per phase

Output Regulation
• Load regulation (constant voltage mode): <0.1% variation for 50–100% load current; <0.05% variation below 50% output
• Load regulation (constant current mode): <0.1% variation for 50–100% load voltage; <0.05% variation below 50% output
• Output ripple: worst-case specified under all resistive load conditions with AC input within specification
• Ripple measured at 50% output voltage and current; decreases toward full rating

Thermal Derating
• Rated output: 0°C to 40°C ambient
• 50°C ambient: 10% derating of 40°C current ratings

– Key Features

• Internal RFI filter with ferrite toroidal chokes
• VDE-listed "X" and "Y" capacitors for EMI suppression
• VDE 875 Level N and VDE 871 Level A compliance for line-conducted RFI reduction
• Wide AC input voltage tolerance with soft-start conditioning
• Tight load and line regulation across full output range
• Flexible input voltage configurations

– Typical Applications

Industrial environments demanding precise DC power with minimal EMI emissions and high immunity to AC line disturbances.

– Compatibility & Integration

Standard industrial AC line inputs (47–63 Hz) with phase-independent operation; external AC source conditioning not required within specified voltage tolerances.

MPN

TCR500T10

Frequency Range

47 to 63 Hz

Voltage / Current Range

115 VAC / 208–220 VAC / 230 VAC input; 46 A per phase at 10 kW