The Madell TPR-3005 is a linear regulated DC power supply engineered for precision test and measurement applications. Dual adjustable outputs deliver 0–30 V DC at 0–5 A per channel, complemented by a dedicated fixed 5 V/3 A output. The supply operates in independent, series, or parallel modes—selectable via front-panel switches—enabling output voltages up to 60 V or combined currents to 10 A. Constant voltage and constant current regulation modes provide stability to ±0.01% + 2 mV (at ≤3 A) with ripple below 0.5 mVrms. Comprehensive protection includes overload, short-circuit, overheat, and overvoltage circuits. Dual digital displays monitor output voltage and current in real time. Low noise performance, fast transient restore (≤100 µs), and minimal temperature drift (≤300 ppm/°C) support demanding laboratory and production environments. AC input accepts 110 V ±10% 60 Hz or 220 V ±10% 50 Hz.
Technical Specifications
Output & Configuration
• Adjustable outputs: 0–30 V DC, 0–5 A per channel
• Fixed output: 5 V DC, 3 A
• Series mode: 0–60 V DC, 0–5 A
• Parallel mode: 0–30 V DC, 0–10 A
Regulation Performance (CV Mode)
• Voltage stability: ≤0.01% + 2 mV (current ≤3 A); ≤0.01% + 5 mV (current >3 A)
• Ripple & noise: ≤0.5 mVrms (≤3 A); ≤1.0 mVrms (>3 A)
• Transient restore: ≤100 µs (5 Hz–1 MHz, ≤3 A)
• Temperature coefficient: ≤300 ppm/°C
Regulation Performance (CC Mode)
• Current stability: ≤0.2% + 2 mA
• Ripple & noise: ≤2 mArms to ≤3 mArms
Input
• AC 110 V ±10% 60 Hz or AC 220 V ±10% 50 Hz
– Key Features
• Dual-output topology with three operational modes (independent, series, parallel) via built-in switches
• CV/CC cross-over regulation with independent control per channel
• Digital voltage and current displays for all outputs
• Overload, short-circuit, overheat, and overvoltage protection
• Low ripple (<0.5 mVrms) and excellent load regulation
– Typical Applications
• Component characterization and testing
• Power supply validation in prototype development
• Laboratory bench work requiring dual independent sources
• Production test where higher voltage or current is needed via series/parallel configuration
– Compatibility & Integration
Standard output terminals support direct load connection. Mode selection uses mechanical switches; no external connections required for series or parallel operation.