The NI PXI-1002 is a 4-slot 3U PXI chassis engineered for test and measurement applications requiring compact, modular instrumentation. It accepts both 3U PXI and 3U CompactPCI modules across one controller slot and three peripheral slots, with three additional controller expansion slots. The chassis delivers 170 W maximum usable output power via 3.3 VDC, 5 VDC, and 12 VDC supplies, powered by universal AC input (90–135 VAC or 180–265 VAC auto-selectable, 47–63 Hz). Forced-air cooling with two 60 cfm fans provides 300 W total cooling capacity and maintains operation across 0 to 50 °C. An internal 10 MHz reference clock and full PXI specification compliance enable precise triggering, star trigger bus support, and module-to-module local bus connectivity. The chassis measures 8.4 × 10.1 × 7.5 inches, weighs 9.5 lb, and ships with optional 19-inch rack-mount capability. Mean time between failures reaches 115,000 hours in AC mode and 79,000 hours in AC/DC mode.
Technical Specifications
• Slots: 4 total (1 controller, 3 peripheral); 3 controller expansion slots
• Module Compatibility: 3U PXI and 3U CompactPCI modules
• Power Output: 3.3 VDC, 5 VDC, 12 VDC supplies; 170 W maximum usable
• Input Power: 90–135 VAC or 180–265 VAC (auto-selectable), 47–63 Hz; 8 A @ 115 VAC; 5 A @ 230 VAC
• Reference Clock: Internal 10 MHz
• Cooling: Filtered forced-air, 2 fans, 60 cfm per fan, 300 W total capacity
• Operating Temperature: 0 to 50 °C
• Storage Temperature: -40 to +70 °C
• Humidity: 10 to 90%, non-condensing
• Dimensions: 8.4 × 10.1 × 7.5 inches
• Weight: 9.5 lb
• MTBF: 115,000 hours (AC mode); 79,000 hours (AC/DC mode)
• Safety Standards: UL 3111-1, IEC 1010-1, CSA 22.2 No. 1010.1; Installation Category II, Pollution Degree 2, Safety Class 1
– Key Features
• Full PXI and CompactPCI specification compliance
• Star trigger bus with high-precision synchronization
• Module-to-module local bus support
• Universal AC input with auto-voltage selection
• Integrated, independently cooled power supply
• Modular construction with optional rack-mount kit
• Minimum 3.0-inch airflow clearance required
– Typical Applications
• Portable test and measurement systems
• Space-constrained laboratory environments
• Production ATE with distributed module architectures
– Compatibility & Integration
Accepts standard 3U PXI and CompactPCI modules across dedicated peripheral and controller expansion slots. Supports all PXI-defined trigger signals and precision clock distribution for multi-module synchronization.