The Power One PFC375-S132 is a 375 W continuous AC-to-DC power supply designed for industrial and commercial electronics requiring active Power Factor Correction. It operates from 85–265 VAC across 47–63 Hz with a power factor of 0.98 per EN61000-3-2 and delivers peak output of 450 W for up to 60 seconds at 10% duty cycle maximum. The unit features overtemperature, overvoltage, and overcurrent protection with 20 mS hold-up time across the full AC input range.
Technical Specifications
Power Output
• Continuous: 375 W
• Peak (60 s, 10% duty cycle): 450 W
• Switching frequency: 100 kHz
• Minimum efficiency: 68% at full rated load, 110 VAC
• Hold-up time: 20 mS at full rated load
Input Specifications
• Voltage range: 85–265 VAC
• Frequency: 47–63 Hz
• Input current: 6 ARMS at 85 VAC, full load
• Inrush current (thermistor-limited):
– 35 APK at 110 VAC (one cycle, 25°C)
– 65 APK at 220 VAC (one cycle, 25°C)
• AC input protection: F10A, 250 V fuse
• Brown-out regulation maintained to 85 VAC
Output Control & Monitoring
• Main channel current sharing (up to 6 parallel units): 10% accuracy
• Remote sense for voltage compensation
• Inhibit function: TTL-compatible logic (low inhibits)
• Power Fail signal: TTL-compatible
• DC Power Good signal available
• Overvoltage protection: 415 Vdc maximum
Thermal & Protection
• Cooling requirement: 300 LFM forced-air
• Overtemperature shutdown with automatic reset
• Multiple protection layers: overcurrent, overvoltage, overtemperature
– Key Features
• Active Power Factor Correction (PFC) per EN61000-3-2
• Wide AC input range enables global deployment
• SAE mounting standard; metric option available
• Optional factory-installed cooling fan
• CE Mark regulatory compliance
• Supports redundant configurations with current sharing
– Typical Applications
• Industrial AC-to-DC conversion systems
• Harmonic reduction in commercial power architectures
• Redundant power configurations requiring current sharing
• Equipment operating across 110–230 VAC utility networks
– Compatibility & Integration
Remote sense capability corrects for cable voltage drops across distributed loads. TTL-compatible control signals integrate with standard logic circuits. Parallel operation supports up to 6 units with 10% current-sharing accuracy for N+1 or load-sharing redundancy. Multiple output models require minimum loads of 3.5 A (5V) or 1 A (24V); single-output configurations accept 0 A minimum.