The Sorensen DCR60-30B is a 1800 W DC power supply delivering 0–60 Vdc at 0–30 A for laboratory, industrial, and burn-in testing applications. Built around SCR or Triac phase control followed by passive LC filtering, this unit maintains tight regulation across its operating envelope while supporting both constant voltage and constant current modes with automatic crossover.
Technical Specifications
Output Characteristics
• Voltage: 0–60 Vdc
• Current: 0–30 A
• Power: 1800 W
• Line and Load Regulation: 0.03%
• Voltage Regulation (CV mode): 0.05% or 10 mV, whichever is greater
• Current Regulation (CC mode): 0.15% of I, max after 30 minute warm-up, 8 hour rating
• Ripple: 125 mV RMS / 375 mV peak-to-peak
• Output Stability: 0.1% E, max and 0.15% of I, max (8 hour after warm-up)
• Temperature Coefficient: 0.03%/°C
• Transient Response: 50 ms typical at 50% load change
Input Requirements
• Standard: 103–127 VAC, single phase, 27.0 A, 50/60 Hz
• Optional: 208, 220, or 230 VAC single phase configurations available
– Key Features
• Dual potentiometer voltage and current adjustment (FINE and COARSE controls)
• Remote sensing capability with 5% E, max or 3 V maximum drop per load lead
• Voltage, current, resistance, and signal programming support
• Remote programming interfaces for voltage and current
• Overvoltage protection with crowbar function and OVP control
• Short circuit and overload protection on output
• Wide temperature operating range enabled by SCR/Triac input control and passive filtering
– Typical Applications
• Burn-in testing of electronic components and assemblies
• Industrial control system validation
• General laboratory power delivery
• Applications requiring stable, regulated DC with tight load and line regulation
– Compatibility & Integration
Output connection via rear terminal strip (TB2). Front panel circuit breaker and adjustment controls. Supports both local manual control and remote programming via accessible signal interfaces.