The Sorensen DHP120-16 is a single-output DC power supply delivering 120V at 16A for demanding test, research, and development applications. Operating in constant voltage, constant current, and constant power modes, this unit combines precise programmability with analog and digital control interfaces. The supply features 0.1% voltage regulation, 0.5% current regulation, and exceptional output stability of ±0.05% over 8-hour intervals. Second-generation control technology enables up to 9 auto-sequence steps with durations from 1 second to 99,999 seconds, making it suitable for complex test protocols and unattended operation.
Technical Specifications
• Output Voltage: 120V maximum
• Output Current: 16A maximum
• Power Output Range: 2 kW to 30 kW across DHP family
• Operating Modes: Constant Voltage, Constant Current, Constant Power
• Voltage Regulation: 0.1% of maximum rated output
• Current Regulation: 0.5% of maximum rated output
• Stability: ±0.05% of maximum rating per 8 hours (post warm-up at fixed line and load)
• Voltage Programming Resolution: 0.3% of full scale
• Current Programming Resolution: 0.3% of full scale
• Voltage Programming Accuracy: 0.10% + 0.3% of maximum output
• Current Programming Accuracy: 0.3% + 0.3% of full scale output current
• Voltage Temperature Coefficient: 0.02%/°C of rated output voltage
• Current Temperature Coefficient: 0.03%/°C of rated output current
• Transient Response: 2 ms to steady state for 30% step load change
– Key Features
• 9 programmable auto-sequence steps (1 second to 99,999 seconds per step)
• Remote sense terminals for point-of-load voltage monitoring (3% line drop maximum per line or 2V, whichever is less)
• External shutdown capability via contact closure
• Power-Off Memory with LAST SET button restoration
• Front-panel soft calibration without chassis removal
• Overvoltage protection (OVP) limit adjustment
• Summary fault status monitoring
• Up/Down arrow controls for voltage and current adjustment
– Typical Applications
High-power testing environments requiring multi-step sequencing, burn-in procedures, and unattended test cycles where output stability and precise regulation are critical.
– Compatibility & Integration
Analog control via 0-5 VDC or 0-10 VDC sources. Remote control and monitoring interfaces support IEEE-488.2, RS 232, and isolated analog input options. On/off control accepts 6-120 VDC, 12-240 VAC, TTL, or CMOS logic switching. Output voltage and current monitoring available at 0-10V.