The Teledyne LeCroy CP031A is a high-sensitivity current probe designed for accurate measurement of AC and DC currents up to 30A, featuring a wide bandwidth of 100 MHz. It provides precise current measurements for various electronic applications. With its high sensitivity, it can detect even small currents, making it suitable for testing low-power devices and circuits.

Request CalibrationRequest Repair
Product Starting From:

$6,479.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote CP031A
Equipment info

The Teledyne LeCroy CP031A is a high-sensitivity current probe engineered for precise AC and DC current measurement up to 30A across a 100 MHz bandwidth. Designed for power electronics, low-power circuit analysis, and detailed device characterization, this probe delivers 10 mV/A sensitivity on the 5A range and 3.33 mV/A on the 30A range, with DC accuracy of ±1% of reading and phase accuracy of ±1° @ 100 kHz. The probe supports a maximum common mode voltage of 600 VRMS CAT III, exhibits noise below 2.5 mA RMS, and achieves response times under 3.5 ns with slew rates exceeding 10 A/µs. Integration with Teledyne LeCroy oscilloscopes via the probe interface enables automatic scaling and de-skewing for streamlined measurements in development and test environments.

Technical Specifications

Electrical Characteristics
• Measurement range (DC to 100 MHz): 5A range—500 mA/div to 5 A/div; 30A range—1 A/div to 30 A/div
• Output voltage: 10 mV/A (5A range), 3.33 mV/A (30A range)
• Bandwidth: 100 MHz (-3 dB)
• Accuracy: ±1% of reading (DC and AC, 50 Hz to 100 MHz)
• Phase accuracy: ±1° @ 100 kHz
• DC input impedance: 1 MΩ
• AC input impedance: 10 µH shunt
• Maximum common mode voltage: 600 VRMS CAT III
• Noise: < 2.5 mA RMS
• Offset current: 10 A/µs
• Response time: 80 dB (DC), > 60 dB (1 kHz), > 30 dB (100 MHz)

Environmental
• Operating temperature: 0°C to 50°C
• Storage temperature: -20°C to +70°C
• Operating humidity: 10% to 80% RH (non-condensing)

– Key Features

• BNC output connector for direct oscilloscope integration
• Smart probe interface with automatic scaling and de-skewing
• Selectable 5A and 30A measurement ranges
• High phase accuracy for power factor and efficiency analysis
• Low offset current and noise for reliable small-signal detection

– Typical Applications

• Power converter and inverter switching loss analysis
• Motor drive current characterization
• Quiescent and standby current measurement in battery-powered systems
• IoT device power profiling

– Compatibility & Integration

The CP031A connects directly to Teledyne LeCroy oscilloscopes equipped with compatible smart probe interfaces. Power and communication are supplied through the probe interface; verify oscilloscope compatibility before deployment.

MPN

CP031A

Frequency Range

DC to 100 MHz

Voltage / Current Range

5A range: 500 mA/div to 5 A/div; 30A range: 1 A/div to 30 A/div; 600 VRMS CAT III common mode

Brand Name

Teledyne LeCroy

You May Also Like