The Teledyne LeCroy WAVEPULSER-40IX is a high-speed interconnect analyzer that combines frequency-domain and time-domain measurements in a single acquisition. Operating across DC to 40 GHz, it characterizes S-parameters, impedance profiles, and signal integrity of advanced serial data interconnects. The instrument delivers 8.5 ps rise time and sub-millimeter spatial resolution, enabling precise validation of cables, connectors, backplanes, and high-speed digital interfaces.
Technical Specifications
Frequency & Bandwidth
• Operating range: DC to 40 GHz
• Rise time (20%–80%): 8.5 ps
• Step/impulse rise time: 8.5 ps
S-Parameter Measurements
• Frequency range: DC to 40 GHz
• Supported configurations: Single-ended, mixed-mode, differential
• Return loss and insertion loss characterization
Impedance Profiling
• Spatial resolution: < 1 mm
• Differential and common-mode impedance profiles
• TDR and TDT (Time Domain Transmission) capabilities
Calibration
• Type: Internal, automatic OSLT (Open, Short, Load, Thru)
• Built-in calibration standards included
• Automated process requiring only DUT connection
– Key Features
Signal Integrity Analysis
• Advanced de-embedding using time gating and 2Xthru techniques
• Fixture, connector, and cable effect removal via TDR-based impedance profiling
• Eye diagram emulation with equalization (CTLE, DFE, FFE)
Jitter Quantification
• Total (Tj), random (Rj), and deterministic (Dj) jitter analysis
• Full deterministic jitter deconvolution
• Multiple jitter visualization options
Simulation-Ready Measurements
• S-parameter de-embedding
• Waveform signal simulator
• Physical-layer response emulation
• Complete NRZ and PAM serial data analysis
Physical Design
• Compact form factor: 105 mm × 305 mm × 230 mm
• Lightweight construction
• 2.92 mm K connectors
• USB host connectivity
– Typical Applications
• Cable and connector characterization
• Backplane validation
• High-speed serial protocol validation
• Signal integrity assessment of demanding electronic systems
– Compatibility & Integration
USB connection to host systems. 2.92 mm K connector interface for measurement ports.