Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

Lambda / TDK / EMI TCR60S10

SKU: TCR60S10Categories: DC Power Supplies
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The Lambda / TDK EMI TCR60S10 is a reliable power supply component. It provides stable power for various electronic applications.

Request CalibrationRequest Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote TCR60S10
Equipment info

The TDK-Lambda EMI TCR60S10 is a 600W single-output DC power supply delivering 60V at 10A for industrial and laboratory applications. This fan-cooled unit combines precise voltage regulation with multiple protective circuits to ensure stable operation across demanding environments.

Technical Specifications

Output Ratings
• Output voltage: 60V
• Output current: 10A
• Output power: 600W

Input Specifications
• Standard AC input: 115V, 47–63 Hz (full range 105–130V)
• Maximum input current at 115V: 9.5A
• Optional AC inputs available: 100V, 200V, 208/220V

Regulation Performance
• Load regulation: <0.1% of output voltage setting (50–100% load); <0.05% below 50% output
• Line regulation: <0.1% of rated output across specified line voltage range; <0.05% below 50% output
• Transient response: Returns to within 2% of final value within 75ms following 30% load step increase
• Output stability: ±0.05% of set point over 8 hours post-warm-up under fixed conditions
• Temperature coefficient: 0.02%/°C (voltage); 0.03%/°C (current)

Protection & Thermal
• Soft-start circuitry eliminates inrush current on power-on and reapplication
• Overvoltage protection: Optional, adjustable 50–110% of rated output with crowbar action
• Overcurrent protection: Integrated
• Thermostat protection on critical circuitry
• Operating temperature: 0°C to 40°C continuous duty
• Storage temperature: −40°C to +85°C

Cooling
• Fan-cooled with horizontal air ducting to minimize thermal coupling between adjacent units

– Key Features

• Single-output configuration for simplified system integration
• Low load and line regulation supporting sensitive analog and digital loads
• Field-adjustable overvoltage protection option
• Tight temperature stability suitable for precision test and measurement

– Typical Applications

Laboratory test benches, industrial process control, R&D prototyping, burn-in testing, and production validation requiring stable, protected 60V sources.

MPN

TCR60S10

Voltage / Current Range

0-10A, 0-60V

Brand Name

Lambda / TDK