The National Instruments PXI-6030E is a multifunction data acquisition module for PXI systems, delivering integrated analog input, analog output, digital I/O, and counter/timer capabilities in a single slot. This 16-bit E Series device supports 16 single-ended or 8 differential analog input channels at up to 100 kS/s per channel, 2 analog output channels at up to 100 kS/s, 8 TTL/CMOS-compatible digital I/O lines, and two 24-bit counter/timers with frequency scaling. Software-configurable input and output ranges eliminate jumper setup, while ±0.5 LSB relative accuracy and guaranteed 16-bit monotonicity ensure measurement precision across temperature ranges from -40°C to +85°C.
Technical Specifications
Analog Input
• 16 single-ended or 8 differential channels
• 16-bit resolution
• Up to 100 kS/s per channel
• Software-selectable bipolar (–Vref to +Vref) and unipolar (0 to Vref) ranges
• ±0.5 LSB relative accuracy
• ±1 LSB maximum DNL (differential nonlinearity)
• Guaranteed 16-bit monotonicity
• 100 GΩ input impedance in parallel with 100 pF
• ±1 nA input bias current
• ±25/15 V input protection (on/off)
Analog Output
• 2 channels
• 16-bit resolution
• Up to 100 kS/s update rate
• Software-selectable unipolar (0 to 10 V) and bipolar (±10 V) ranges
• ±5 mA output current drive
• 0.1 Ω maximum output impedance
Digital I/O & Counters
• 8 TTL/CMOS-compatible digital I/O lines
• ±VCC + 0.5 V protection (on/off)
• 13 mA source current at (VCC – 0.4 V)
• 24 mA sink current at 0.4 V
• Two 24-bit counter/timers (TTL/CMOS compatible)
• One 4-bit frequency scaler
Triggering & Interfaces
• Analog and digital triggering supported
• 68-pin SCSI-II male connector
• PXI Specification Rev 1.0 compliant; compatible with PXI and PXI Express systems
Power & Environment
• Supply voltages: 3.3 V and 5 V
• +5 V output with 1 A source capability
• Operating temperature: -40°C to +85°C
• Maximum altitude: 2,000 meters
• Module dimensions: 6.3 × 3.9 inches
– Key Features
• Single-slot PXI module consolidates multiple I/O functions
• No physical jumpers or switches; all configuration via software
• High input impedance (100 GΩ) minimizes loading effects
• 24-bit counter resolution for precision timing and event counting
• NI-DAQmx driver compatibility with LabVIEW and LabWindows/CVI
– Typical Applications
• Industrial process monitoring and control
• Signal conditioning and data logging
• Laboratory instrumentation and research
• Real-time analog and digital measurements
• Counter and timing applications
– Compatibility & Integration
The PXI-6030E operates within PXI and PXI Express chassis using the NI-DAQmx software suite, enabling rapid development in standard environments. The 68-pin SCSI-II connector provides signal routing to external measurement systems.