Call +1 ‪(484) 841-9341‬

NIST TRACEABILITY 

NIST-traceable calibration certificate available with data

Service Support

Service plans available for the products’ durability

FAST REPAIRS

1–3 day turnaround, 15-day return on repair policy

Software Updates 

Staying up-to-date with latest software updates.

NI PCI-4454 4-Channel Dynamic Signal Acquisition Board

SKU: PCI-4454Categories: Data Acquisition Systems (DAQ)
Brand: NI
30 Days Warranty30 Days Free Returns >

+1 ‪(484) 841-9341‬

  • Repair Support & OEM Spare Parts
  • University and Research Discounts
  • Rental Units Available

The NI PCI-4454 is a high-accuracy, 4-channel dynamic signal acquisition (DSA) board designed for demanding audio, acoustic, and vibration measurement applications. It features 24-bit resolution ADCs, IEPE conditioning, and a high sampling rate, making it ideal for noise and vibration analysis, machine condition monitoring, and audio testing.

Request CalibrationRequest Repair
Product Starting From:

$0.00

In stock

In stock

Credit cards Accepted, Visa, ,mastercard, discover, PAypal, amex
Precision RF and optical test equipment sales, calibration, and repair by Aumictech. Email: sales@aumictech.com

Fastest Shipping. Estimated 2 days

Shipping Expedited across US-Canada:
FedEx, UPS, USPS
Shipping world-wide available:
DHS, FedEx International
Request Quick Quote PCI-4454
Equipment info

The NI PCI-4454 is a 4-channel dynamic signal acquisition board engineered for high-fidelity audio, acoustic, and vibration measurements. It delivers simultaneous sampling across all channels with 16-bit resolution, 51.2 kS/s per-channel throughput, and delta-sigma conversion architecture for superior linearity and low distortion. The board integrates programmable gain amplification, software-selectable AC/DC coupling, and IEPE signal conditioning to accommodate piezoelectric transducers directly. A PCI bus interface enables high-speed data transfer and integration within larger National Instruments measurement systems.

Technical Specifications

Analog Input Channels: 4 single-ended inputs
Resolution: 16-bit ADCs
Sampling Rate: 51.2 kS/s per channel, simultaneous
Bandwidth: DC to 23 kHz
Input Range: ±10 V
Dynamic Range: 90 dB
Programmable Gain: −20 to +60 dB in 10 dB steps
Total Harmonic Distortion: −90 dB at 1 kHz; −80 dB worst-case at higher frequencies
Amplitude Flatness: ±0.1 dB (DC to 95 kHz)
Coupling: AC/DC switchable
Signal Conditioning: IEPE support

Analog Outputs (Optional): 24-bit simultaneous update at 51.2 kS/s
Digital I/O (Optional): 8 TTL-compatible lines
Counter/Timers: 2 × 24-bit channels for timing I/O

– Key Features

• Delta-sigma oversampled converters with integrated anti-aliasing and imaging filters
• External digital trigger (5 V TTL/CMOS, edge-selectable)
• Pretrigger, posttrigger, and delay trigger modes
• Trigger sources from analog inputs, external digital input, RTSI bus, or software
• RTSI bus synchronization for multi-instrument clock alignment
• Simultaneous sampling across all input channels

– Typical Applications

• Vibration and modal analysis
• Acoustic measurement and characterization
• High-fidelity audio signal acquisition
• Transient capture and waveform recording

– Compatibility & Integration

PCI bus interface with NI-DAQ driver support. Compatible with Windows, Linux, and macOS operating systems. Integrates with other National Instruments devices via RTSI synchronization bus.

Weight18 lbs
Dimensions20 × 16 × 10 in
MPN

PCI-4454

Frequency Range

DC to 23 kHz

Voltage / Current Range

±10 V input

Brand Name

NI

You May Also Like