The NI PXI-6040E is a 12-bit multifunction data acquisition module designed for integration into PXI systems. It delivers 16 single-ended (or 8 differential) analog input channels at 500 kS/s aggregate sampling, plus 8 digital I/O lines, 2 counter/timers, and RTSI synchronization for seamless multi-module coordination. Software-selectable input ranges (±10 V, ±5 V, ±1 V, ±0.5 V) and user-calibratable offset/gain errors accommodate diverse signal conditioning requirements. The module operates from the PXI backplane with typical power consumption of 3.0 W, making it ideal for embedded test systems requiring synchronized analog, digital, and timing functions.
Technical Specifications
Analog Input
• 16 single-ended or 8 differential channels
• 12-bit resolution
• 500 kS/s maximum sampling rate (aggregate)
• Input ranges: ±10 V, ±5 V, ±1 V, ±0.5 V (software-selectable)
• DC coupling; 10 MΩ || 100 pF (differential), 5 MΩ || 100 pF (single-ended)
• User-calibratable offset and gain error
Digital I/O
• 8 programmable I/O lines, 5 V TTL/CMOS compatible
• Output drive: 2.4 mA sourcing, 6.4 mA sinking at 2.4 V
• Input thresholds: 0 to 0.8 V (low), 2.0 to 5.25 V (high)
Counter/Timers
• 2 counters, 32-bit resolution
• 20 MHz maximum input frequency
• Pulse measurement, event counting, and generation modes
Timing & Synchronization
• Onboard clock: ±50 ppm accuracy
• RTSI clock: Sub-nanosecond accuracy (synchronized systems)
• Trigger sources: Software, RTSI, PFI
Power
• 3.0 W typical, 5.0 W maximum
• PXI backplane: +5 V, +12 V, -12 V
– Key Features
• PXI single-slot, 3U form factor for modular integration
• Programmable Function Interface (PFI) for external triggering and clocking
• RTSI bus enables sub-nanosecond synchronization across modules
• User-calibratable analog errors reduce external calibration dependencies
– Typical Applications
• Multi-channel sensor data acquisition
• Real-time control and timing measurements
• Synchronized distributed test systems
• Industrial process monitoring
– Compatibility & Integration
Compatible with National Instruments and most third-party PXI chassis. Integrates with NI software platforms for configuration and data streaming.