The TDK-Lambda JWS600-48 is a single-output AC-DC industrial power supply delivering 624W at 48V DC / 13A in a forced-air cooled enclosed format. Universal input accepts 85–265V AC (47–63Hz) or 120–330V DC, with power factor and harmonic correction to EN61000-3-2. Built-in over-current protection (13.7A limit, auto-recovery) and over-voltage protection (55.2–64.8V shutdown, manual reset) safeguard connected loads. Remote sensing, remote ON/OFF control, and power-fail signal output enable flexible system integration. Typical efficiency reaches 83–85% with 20ms hold-up time at nominal conditions. Operating range spans −10 to +65°C with derating above 50°C; output voltage adjustable ±10% via trimmer.
Technical Specifications
• Input: 85–265V AC (47–63Hz) or 120–330V DC
• Output: 48V DC, 43.2–52.8V adjustable range, 13A max, 624W
• Efficiency: 83–85% typical
• Hold-up Time: 20ms at 100/200VAC, nominal voltage, full load
• Inrush Current: 20A @ 100VAC; 40A @ 200VAC
• Cooling: Forced air with blower fan
• Temperature Operating: −10 to +65°C (100% load −10 to +50°C; 70% at +60°C; 55% at +65°C)
• Temperature Storage: −30 to +85°C
• Humidity: 10–90% RH operating; 10–95% RH storage (non-condensing)
– Key Features
• Power factor correction and harmonic correction per EN61000-3-2
• Over-current protection with automatic recovery
• Over-voltage protection with manual reset via line recycle
• Input transient immunity to EN61000-4 (2, 3, 4, 5, 6)
• Remote sensing for load-end voltage regulation
• Remote ON/OFF control capability
• Power-fail monitoring signal (open-collector output)
• Output voltage fine-tuning via V.ADJ trimmer (±10% range)
– Typical Applications
• Industrial automation and control systems
• Test and measurement equipment racks
• Telecom infrastructure power distribution
• Process control and distributed I/O modules
– Compatibility & Integration
Note: JWS600-48 is obsolete. TDK-Lambda recommends HWS600-48 as alternate (interchangeability not guaranteed). Complies with CSA C22.2 No.60950-1, EN60950-1, and UL60950-1 safety standards.