The Sorensen DCR150-12B is a 1800 W DC power supply delivering stable, adjustable power from 0–150 Vdc at 0–12 ADC. Built on SCR-controlled regulation, it combines precise voltage and current control with automatic mode crossover, current limiting, and optional overvoltage protection. The unit operates from 115 VAC single-phase input (103–127 VAC nominal, 50/60 Hz) with optional 208, 220, or 230 VAC configurations, making it suitable for laboratory testing, component burn-in, and automated test equipment requiring tight regulation and low ripple.
Technical Specifications
Power Output: 1800 W | Regulation Architecture: SCR-controlled regulator
Input Voltage: 115 VAC single-phase nominal (103–127 VAC operating range); optional 208, 220, 230 VAC available. 50/60 Hz operation without derating.
Output Voltage: 0–150 Vdc, adjustable across full range | Output Current: 0–12 ADC at 40°C ambient
Voltage Regulation (CV Mode): 0.05% or 75 mV (whichever greater) for combined line and load | Current Regulation (CC Mode): 0.25% of Imax or 32 mA (whichever greater) for combined line and load
Ripple and Noise (PARD): 300 mV RMS in CV mode; 24 mA RMS in CC mode | Temperature Coefficient: Voltage 0.015%/°C of Eomax; Current 0.03%/°C of Iomax
Stability: ±0.1% Eomax voltage / ±0.15% Iomax current over 8 hours following 30-minute warm-up | Transient Response: 50 ms typical to settle within ±1% band on 50–100% step load change
– Key Features
• Adjustable current limiting with automatic recovery protects against overload and short-circuit conditions
• Overvoltage Protection (OVP) standard or optional
• Automatic CV/CC crossover eliminates manual mode switching
• Dual front-panel analog meters with FINE and COARSE voltage/current adjustment potentiometers
• Remote voltage and current programming with low-level remote sensing (±5% Eomax or 3 V maximum lead drop)
• Power circuit breaker and operating-mode indicator lights
– Typical Applications
Laboratory power sourcing, component burn-in testing, automated test equipment operation, and load characterization requiring stable, low-noise DC delivery.
– Compatibility & Integration
Bench or rack-mountable form factor. Weight 15 lbs. Direct operation and parallel connection supported. Remote programming available in voltage and current modes.